Solid-state Timer H3JA Economical, Compact, Plug-in Timer ■ Time limit operation with automatic resetting. ■ DIN size (36 × 36 mm), fits standard 8-pin sock- ets. ■ Wide choice of supply voltages: 24, 100 to 120, 200 to 240 VAC, 12, 24 VDC. ■ Dual LED indication for power and output sta- tuses. ■ Large transparent setting knob. ■ Setting error rating almost matches that of a 48 × 48 timer. ■ Conforms to UL and CSA, and meets CE marking requirements. Ordering Information Operation/resetting system Time-limit operation/ self-resetting Note: Time-limit contact SPDT Mounting method Surface mounting, flush mounting, and DIN track mounting DPDT Rated time Model 1 s, 3 s, 5 s, 10 s, 30 s, H3JA-8A 60 s, 3 min, 5 min, 10 min, H3JA-8C 30 min, 60 min, 3 hrs Specify the model number, supply voltage, and rated time when ordering. Ex. H3JA-8A 100 to 120 VAC 1 s Rated time Supply voltage ■ Accessories (Order Separately) Name/specifications Flush Mounting Adapter Mounting Track Models Y92F-31 50 cm (l) × 7.3 mm (t) PFP-50N 1 m (l) × 7.3 mm (t) PFP-100N 1 m (l) × 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Track Mounting/ Front Connecting Socket 8-pin PF085A Back Connecting Socket 8-pin US08 8-pin P3G-08 8-pin, finger safe type P3G-08 with Y92A-48G (see note 1) For PF085A Socket Y92H-6 Hold-down Clip (see note 2) Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. 2. Hold-down Clips are sold in sets of two. 1 H3JA H3JA Specifications ■ Time Ranges Rated time 1s Time range 0.1 to 1 s Rated time Time range 3 min 0.3 to 3 min 0.5 to 5 min 3s 0.3 to 3 s 5 min 5s 0.5 to 5 s 10 min 1 to 10 min 10 s 1 to 10 s 30 min 3 to 30 min 30 s 3 to 30 s 60 min 6 to 60 min 60 s 6 to 60 s 3 hrs 0.3 to 3 hrs ■ Ratings Rated supply voltage 24, 100 to 120 or 200 to 240 VAC (50/60 Hz); 12, 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption H3JA-8A 100 to 120 VAC: 200 to 240 VAC: 24 VAC: 24 VDC: 12 VDC: H3JA-8C 100 to 120 VAC: 200 to 240 VAC: 24 VAC: 24 VDC: Control outputs 2 Approx. 2.6 VA (1.1 W) at 120 VAC Approx. 5.0 VA (1.5 W) at 240 VAC Approx. 1.0 VA (0.9 W) at 24 VAC Approx. 0.8 W at 24 VDC Approx. 0.5 W at 12 VDC Approx. 2.4 VA (0.9 W) at 120 VAC Approx. 4.1 VA (1.1 W) at 240 VAC Approx. 1.2 VA (1.0 W) at 24 VAC Approx. 0.8 W at 24 VDC H3JA-8A: 7 A at 250 VAC, resistive load H3JA-8C: 5 A at 250 VAC, resistive load H3JA ■ H3JA Characteristics Accuracy of operating time ±2% max. (full scale) Setting error ±7% max. (full scale) ±50 ms at 20°C Influence of voltage ±2% max. (full scale) Influence of temperature ±5% max. (full scale) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and between contact-carrying and control circuit, and between contacts of different poles) 750 VAC, 50/60 Hz for 1 min (between non-continuous contacts: H3JA-8A) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts: H3JA-8C) Impulse withstand voltage 3 kV (between power terminals) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) Noise immunity ±1.5 kV (between power terminals) and ±1.5 kV (between output terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Destruction: 8 kV Malfunction: 6 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude in 3 directions for 1 hour each. Malfunction: 10 to 55 Hz with 0.5-mm double amplitude in 3 directions for 10 minutes each. Shock resistance Destruction: 1,000 m/s2 Malfunction: 100 m/s2 Ambient temperature Operating: Storage: –10°C to 55°C –25°C to 65°C Ambient humidity Operating: 35% to 85% Life expectancy H3JA-8A Mechanical: Electrical: H3JA-8C Mechanical: Electrical: 10,000,000 operations min. 60,000 operations min. (7 A resistive load at 250 VAC, 360 operations/h) 10,000,000 operations min. 100,000 operations min. (5 A resistive load at 250 VAC, 360 operations/h) EMC (EMI) Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B Harmonic Current: EN61000-3-2 Voltage Fluctuation and Flickering: EN61000-3-3 (EMS) Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3) 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3) 1 kV differential mode (level 3) Approved standard UL508 (See note.), CSA C22.2 No. 14, conforms to EN61812-1 (Pollution degree 2) Case color Light gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight H3JA-8A: Approx. 50 g H3JA-8C: Approx. 60 g Note: The surrounding air temperature (operating) is −10 to 40°C. 3 H3JA H3JA Engineering Data H3JA-8C 5,000 Switching operations (× 10 3 ) Switching operations (× 10 3 ) H3JA-8A 30 VDC resistive load 1,000 120 VAC resistive load 500 30 VDC inductive load 120 VAC 100 L/R = 7 ms inductive load cosφ = 0.4 250 VAC 50 resistive load 0 1 2 3 4 5 6 φ 7 Load current (A) Load current (A) Operation ■ Timing Chart H3JA-8A 100 ms min. Rt Terminals (2)-(7) (power) Set time Set time (6)-(8) (NO) (5)-(8) (NC) Time UP indicator (Orange) Power ON indicator (Green) 100 ms min. H3JA-8C Rt Terminals (2)-(7) (power) Set time (1)-(3) (NO) (6)-(8) (1)-(4) (5)-(8) (NC) Time UP indicator (Orange) Power ON indicator (Green) 4 Set time H3JA H3JA Dimensions Note: All units are in millimeters unless otherwise indicated. 7 36 LED 36 ■ 60 14.2 4 0.7 30.5 32.8 Accessories (Order Separately) Flush Mounting Adapter Y92F-31 Adapter Y92F-31 shown with H3JA-8@ and back connecting socket. Panel Cutout Recommended panel thickness: 1 to 5 mm 15.5 US08 46 40 13 44 US08 Connecting Socket 37.4 22 11 91.3 Track Mounting/Front Connecting Socket PF085A Eight, M3.5 × 7 sems Terminal Arrangement (Top View) Mounting Holes Two, M4 or 4.5 dia. holes Mounting Height of Timer with Socket Two, 4.5 dia. holes H3JA Note: PF085A can be used as a front connecting socket. Hold-down Clips (Set of Two Clips) Y92H-6 for PF085A Socket 5 H3JA H3JA Back Connecting Socket US08 US08 H3JA + Adapter P3G-08 11 Terminal Arrangement (Bottom View) 91.3 (When Y92A-48G mounted) P3G-08 H3JA + Adapter 4.9 17 11 78.6 85.1 Finger Safe Terminal Cover Conforming to VDE0106/P100 Twelve, 6.4 dia. holes Y92A-48G (Attachment for P3G-08 Socket) 48 × 48 47.7 × 47.7 34 16.5 24.6 27.6 47.4 Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 35±0.3 15 25 25 10 25 1,000 (500) (see note) 25 10 15 (5) (see note) Note: The values shown in parentheses are for the PFP-50N. 6 35±0.3 27±0.15 1 15 25 10 25 15 25 25 1,000 10 27 24 29.2 1 1.5 H3JA H3JA End Plate PFP-M Spacer PFP-S 10 16 12 5 6.2 1.8 1 50 1.8 11.5 10 M4 × 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 Installation ■ Terminal Arrangement H3JA-8A H3JA-8C 7 H3JA H3JA ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L110-E1-01A In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Control Devices Division H.Q. Analog Controller Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7080/Fax: (81)75-344-7189 0707
H3JA-8C AC100-120 30S
物料型号:H3JA

器件简介:H3JA是一款经济实惠、体积小巧的插入式定时器,具有自动复位的时间限制操作功能。它适用于DIN尺寸(36×36mm),适配标准的8针插座。提供多种供电电压选择,包括24V、100至120V、200至240VAC,以及12V、24VDC。具有双LED指示灯,分别显示电源和输出状态。设置旋钮大且透明,设置误差几乎与48×48定时器相当。符合UL和CSA标准,并满足CE标记要求。

引脚分配:文档中提供了详细的引脚分配图,但未列出具体的引脚功能。

参数特性:H3JA提供多种额定时间选项,从1秒到3小时不等。供电电压范围广泛,包括交流和直流选项。功率消耗和控制输出能力也根据不同的供电电压而变化。

功能详解:H3JA具有高精度的运行时间,设置误差小,受电压和温度影响较小。绝缘电阻高,抗电强度好。具有抗干扰能力,包括抗噪声干扰和静电放电干扰。

应用信息:H3JA适用于需要时间控制的各种工业自动化应用。

封装信息:H3JA的尺寸为36×36mm,适合DIN轨道安装,也支持表面安装和嵌入式安装。提供多种安装配件,如安装轨道、端板、垫片等。